IPR IS OFFERING SIGN ON BONUSES FOR QUALIFIED CANDIDATES

$5,000 for CDLs - Applies to valid Class A or Class B

$1,000 paid upon completion of your 90-day evaluation
$1,500 paid after 6 months
$2,500 paid after 12 months

 

$1,000 for any field labor position with a driver’s license

Paid upon completion of your 90-day evaluation

 

Apply now to our current job opportunities at https://www.indeed.com/cmp/Inland-Pipe-Rehabilitation/jobs
Program valid through December 31, 2021.*

 

*Program governed by the terms and conditions set forth in IPR’s policies.*

 

Project Owner: Washington Suburban Sanitary Commission (WSSC)

IPR Northeast, LLC – ITB: Certified MBE/SLBE Firms

Approved Certification Agencies: Maryland DOT | Prince George's County Supplier Development & Diversity Division (SDDD) | District of Columbia's Department of Small and Local Business Development (DC-DSLBD | Capital Region Minority Supplier Development Council (CRMSDC) | Women's Business Enterprise Council Greater DMV (WBEC)| 6a. Small Local Business Enterprise (SLBE) Firms approved by WSSC | 6b. Small Local Business Enterprise (SLBE) Firms – Service-Disabled Veterans

(SDV) approved by WSSC | WSSC 

Project Owner: Washington Suburban Sanitary Commission (WSSC)

Project Title: JOB # CI/CR/LL/LR7125B21, Contract #CI5335A17 – Task Order 310- IDIQ ESA Sewer Main Repair, Replacement & Rehab. in Prince George County, Maryland within the Piscataway Creek Basin

Bid Date: 02/08/22

Quotes Returned: 02/03/22 – 5:00 P.M.EST


Scopes:

Clean/CCTV

  • 3456 LF 8”          
  • 142 LF 10”
  • 243 LF 12”
  • 359 LF 8” Diameter Sewer – Light Cleaning with Video Inspection
  • 900 LF 8” Diameter Sewer – Heavy Cleaning with Video Inspection

Open Cut

  • Replace Sanitary Sewer Pipe 8”at 0’-12’ Depth
  • Replace Sanitary Sewer Pipe 8” at 12’-20’ Depth
  • Replace Sewer House Connection 4” by Excavation; 0’-12’ Depth
  • Replace Sewer House Connection 4” by Excavation; 12’-20’ Depth
  • 8” Diameter pipe Sewer External Point Repair at 0’-12’ Depth
  • 8” Diameter pipe Sewer External Point Repair at 12’-20’ Depth
  • Joint, Defect - 8" Diameter Sewer Pipe
  • Locate Existing Buried Manhole - In Unpaved Area
  • Reset/Set Manhole Frame and Cover
  • Furnish New 24”-36” Manhole Frame and Cover
  • Manhole Grade Ring Adjustment
  • Prince George's County Roads Restoration
  • 4” Concrete Sidewalk
  • 6” Concrete Driveway
  • Curb and Gutter Replacement
  • Gravel- Trench Backfill
  • Borrow Material- Trench Backfill (Replacement of unsuitable material)
  • GAB: Graded Aggregate Base

Manhole Rehab

  • 8” Lateral-Mainline Interface Sealing
  • Chimney Seal

Pipe Bursting

  • 1313 LF 8” Diameter Sewer Pipe Bursting

Erosion Control

  • Street – Trees
  • Pruning (Trimming)
  • Tree Removal (greater than 4” DBH)
  • Grind Stump and Surface Roots (greater than 6" at grade)


Specs/Plans – Jennifer Elder | jelder@teamipr.com | 404-927-4603

slideup